FPU Electrical Engineer #O&G1

Bureau Veritas · Gendalo Gendang, Indonesia · On site · 8 days ago

Sign up to apply
Your first one is free
Posted October 06, 2026 · Read from Bureau Veritas
Why a CV for this job?

94% of employers say their filters drop qualified candidates whose CV does not match the ad's exact criteria (Harvard Business School, 2021).

  • They see what they asked for, first. Your experience that matches the ad leads, in the ad's own words, so someone skimming finds it in seconds.
  • It gets past the software. Many larger employers use software that ranks CVs by how closely they match the ad, often before anyone reads them.
  • In the language of the ad. An ad written in Spanish gets a CV in Spanish, even when yours is in Portuguese.
  • Your facts, nothing invented. Your own experience, reordered and reworded. What the ad wants and your CV does not show is listed for you to add, only if it is true. You check it before you send it.
See an example

Qualification:

a) Bachelor Degree in Electrical Engineering (S1) from university in Indonesia.

b) Minimum 10 years experiences in relevant electrical engineering design upstream oil and gas facilities topside facilities.

c) Experience with the Electrical Specification and Design Criteria, Electrical Load Analysis, Major Electrical Equipment Sizing (such as AC/DC UPS and Battery Sizing, Cable Sizing, Main Switchgear/MCC Sizing, Distribution Panel Sizing, Lighting Calculation), Datasheet, Electrical Drawings (e.g. Single Line Diagram, Main Electrical Equipment Layout, Cable Routing Layout, Cable Schedule, Schematic and Wiring Connection Diagram, Lighting Layout, electrical standard installation detail and etc.), Hazardous Area Classification Concept, Lightning Protection Concept, MTO and Bulk Material.

d) Considerable experience of detail engineering design of major electrical equipment such as MV/LV Switchgear & MCC Panel, AC/DC UPS, VFD, MV/LV Motor, Power Transformer and etc.

e) Experience with the Electrical Power System Study (Load Flow Analysis Study, Short Circuit Analysis Study, Motor Starting Analysis Study, Transient Stability Analysis Study, Protection Coordination Study and etc) by ETAP Software programming.

f) Experience with FAT & SAT of Main Electrical Equipment such as MV/LV Switchgear, AC/DC UPS, Power Transformer, Generator, MV/LV Motor and etc.

g) Experience with Electrical International and National standards such as IEC, NEC, ANSI/NEMA, API, IEEE, ASTM, ATEX, IECEx, NFPA 780 and SNI.

Employer
Bureau Veritas
Location
Gendalo Gendang, Indonesia · On site